TYPE - K.J.E.T.
PRINTING THERMOMETER
Model 422324
INSTRUCTION MANUAL
Vue de la page 0
1 2 3 4 5 6 ... 20 21

Résumé du contenu

Page 1 - INSTRUCTION MANUAL

TYPE - K.J.E.T. PRINTING THERMOMETER Model 422324 INSTRUCTION MANUAL

Page 2 - CONTENTS

Note: voltage VCC to GND is 16V Maximum, 5V Minimum. GND≦SYNC≦VCC Example : High Alarm= 1300.5℃ , Low Alarm= -50.5℃ If LCD reading ≧ 1300.5℃

Page 3

Result : Hi Alarm output reading approx 5V Lo Alarm output reading approx 5V 10. T1/T2 /T1-T2 measurements : Press to select the display method, T1,

Page 4

IV. PRECAUTIONS AND PREPARATIONS FOR MEASUREMENT 1. Before use, examine the device to ensure that no shipping damage has occurred. 2. Save all packi

Page 5

V. OPERATIONAL GUIDE A. This meter can be operated with batteries or 9V Adaptor, If using batteries, remove the rear cover and install the batter

Page 6

3. ALARM UNIT (℃/℉): Fig-7 4. FIRST THREE DIGITS IN HI ALARM (-399~399): Fig-8 5. LAST TWO DIGITS IN HI ALARM (00~99): Fig-9

Page 7

8. HOUR OF INTERVAL PRINTING (00~23): Fig-12 9. MINUTE OF INTERVAL PRINTING (00~59): Fig-13 10. SECOND OF INTERVAL PRINTING (00~59

Page 8 - T 1 K - 0 0 2 3 . 0

13. HOUR OF STOP INTERVAL PRINTING TIME (00~23) : Fig-17 14. MINUTE OF STOP INTERVAL PRINTING TIME (00~59): Fig-18 15. FIRST TW

Page 9

18. DAY DIGITS OF CALENDAR MONTH-DAY (01~31): Fig-22 19. HOUR DIGITS OF CALENDAR HOUR-MINUTE (00~23): Fig-23 20. MINUTE DIGITS OF CALE

Page 10

If interval printing is enabled in the programming mode, the printer will print as in the examples below: 11:54:00 11-02 INTV:00:00:10 First t

Page 11

If the print button is held for 2 seconds, the printer will print as follows: 12:58:18 11-02 INTV:00:00:10 12:58:28 11-02 T1 K –003

Page 12

CONTENTS Title Page I. SAFETY INFORMATION ... 1 II. SPECIFICATIONS ...

Page 13

VI. INTERVAL PRINTING SETUP 1. SETUP INTERVAL PRINT (with 24 hour maximum interval limit).  Enter the Menu mode by pressing the MENU button.  Ena

Page 14

 Support Hotline (781) 890-7440 Tech support: Ext. 200; Email: [email protected] Repair/Returns: Ext. 210; Email: [email protected] Website: www.e

Page 15

I. SAFETY INFORMATION  Read the following safety information carefully before attempting to operate or service the meter.  Use the meter only as

Page 16

II. SPECIFICATIONS 2-1 General Information Display: 4-1/2 digit LCD LCD illustration (see below) Fig-1 T1-T2 , T2 , T1 Reflects the selected

Page 17

Over Range or - appears. Low battery indicator Sampling Rate 1 reading per second (approx.) Pow

Page 18

Printer Thermo-printing type with 16 characters per line using 38mm width plain thermo-paper. Instant printing: Print on demand (button press) Inter

Page 19

III. Description of Thermometer Fig-2 1. LCD Displays readings, units, symbols, and decimal points 2. POWER Powers the unit on/off 3. UNIT Selec

Page 20

4. PRINT  Prints current measurement (print format shown below): LINE 1 1 0 : 5 1 : 1 2 1 1 - 0 2 LINE 2 T 1 K - 0 0 2 3 . 0 C Line 1:

Page 21 - Version 1.0 August 2002

9. High / Low Alarm output connector Fig-4 Pin 1: GND ( external supply low voltage ) Pin 2: VCC ( external supply high voltage ) Pin 3: SYNC (