9
CONTINUITY CHECK
WARNING: To avoid electric shock, never measure continuity on circuits or wires that
have voltage on them.
1. Set the function switch to the green position.
2. Insert the black lead banana plug into the negative COM jack.
Insert the red test lead banana plug into the positive Ω jack.
3. Press the MODE button to indicate“ "and “ on the display
4. Touch the test probe tips to the circuit or wire you wish to
check.
5. If the resistance is less than approximately 35Ω, the audible
signal will sound. If the circuit is open, the display will indicate
OL”.
DIODE TEST
1. Set the function switch to the green position.
2. Insert the black test lead banana plug into the
negative COM jack and the red test lead banana
plug into the positive V jack.
3. Press the MODE button to indicate “ “ and “Von
the display.
4. Touch the test probes to the diode under test.
Forward voltage will typically indicate 0.400 to
0.700V. Reverse voltage will indicate “OL”. Shorted
devices will indicate near 0V and an open device will
indicate “OL” in both polarities.