Instruction Manual
MODEL 382860
True RMS Power MultiMeter
1. INTRODUCTION
Congratulations on your purchase of the Extech Model 382860 True RMS Power MultiMeter.
Four LCD displays offer four simultaneous readings e.g. during “POWER” measurements,
simultaneous displays of power, current, AC voltage and power factor can be viewed; AUTO
RANGE always selects the correct measuring range to achieve best accuracy; REL
(Relative) function allows the operator to measure a value with respect to a preset reference
value; CMP (Comparator) function allows a comparative measurement to be made (the
upper/lower limits can be defined); MEM (Memory) and RCL (Recall) functions permit 10
measurements to be stored in memory for later recall; AUTO-POWER-OFF extends the life of
the battery by turning off the meter if neither the rotary function switch nor any button is
operated for 12 minutes. The AC Adaptor required for Power measurements is included.
Vue de la page 0
1 2 3 4 5 6 ... 15 16

Résumé du contenu

Page 1 - True RMS Power MultiMeter

1 382860 Ver. 1.5 2/01 Instruction Manual MODEL 382860 True RMS

Page 2

10 382860 Ver. 1.5 2/01 2. Connect the test-leads to the device under test. Ensure that all power is rem

Page 3

11 382860 Ver. 1.5 2/01 6.7 Capacitance Measurement Attention: When shorting capacitors (discharging), hi

Page 4

12 382860 Ver. 1.5 2/01 4. Now connect the other end of the black test-lead to the “ground” point of the

Page 5

13 382860 Ver. 1.5 2/01 Main LCD Left sub-LCD Center sub-LCD Right sub-LCD Mode 0 Watts AC Load Cu

Page 6

14 382860 Ver. 1.5 2/01 Switch setting from POWER with the Adaptor connected. Serious injury and meter da

Page 7

15 382860 Ver. 1.5 2/01 9.2.2 Using the Windows Software Follow these steps to install and run the Windo

Page 8

16 382860 Ver. 1.5 2/01 11. REPAIR AND CALIBRATION SERVICES Extech offers complete repair and calibration

Page 9

2 382860 Ver. 1.5 2/01 2. SPECIFICATIONS 2.1 General Specifications Display One Main and three Sub 3-3/4

Page 10

3 382860 Ver. 1.5 2/01 Mode Measuring Range Accuracy Resolution 4kHz 1Hz 40kHz 10Hz 400kHz 100H

Page 11

4 382860 Ver. 1.5 2/01 3. METER DESCRIPTION Function Keys: • Power ON/OFF Key • FUNCTION Select Key

Page 12

5 382860 Ver. 1.5 2/01 • To avoid an electrical shock, don’t touch directly or indirectly the test probe

Page 13

6 382860 Ver. 1.5 2/01 5. BASIC METER OPERATION 5.1 Quick Start • Connect the test leads to the meter

Page 14

7 382860 Ver. 1.5 2/01 • mA-Measuring Socket For DC/AC mA current measurements below 400mA, insert the

Page 15

8 382860 Ver. 1.5 2/01 • MEM (Memory): Up to 10 measurements (0 to 9) can be stored and recalled. Press

Page 16

9 382860 Ver. 1.5 2/01 6. MEASUREMENT INSTRUCTIONS 6.1 Voltage AC/DC Measurements (True RMS for AC Volta